This is the latest recevied telemetry packets stored in our database for station/object SQ9IKM-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1775645352 | 210 Count | 326 Count | 105 Count | 0 VDC | 0 VDC |
| 1775644451 | 208 Count | 323 Count | 104 Count | 0 VDC | 0 VDC |
| 1775643551 | 205 Count | 320 Count | 102 Count | 0 VDC | 0 VDC |
| 1775642650 | 202 Count | 316 Count | 100 Count | 0 VDC | 0 VDC |
| 1775641749 | 200 Count | 313 Count | 99 Count | 0 VDC | 0 VDC |
| 1775640849 | 197 Count | 309 Count | 97 Count | 0 VDC | 0 VDC |
| 1775639948 | 196 Count | 307 Count | 97 Count | 0 VDC | 0 VDC |
| 1775639047 | 194 Count | 306 Count | 96 Count | 0 VDC | 0 VDC |
| 1775638147 | 192 Count | 305 Count | 95 Count | 0 VDC | 0 VDC |
| 1775637246 | 189 Count | 303 Count | 93 Count | 0 VDC | 0 VDC |
| 1775636345 | 187 Count | 302 Count | 92 Count | 0 VDC | 0 VDC |
| 1775635445 | 185 Count | 300 Count | 91 Count | 0 VDC | 0 VDC |
| 1775634544 | 183 Count | 299 Count | 90 Count | 0 VDC | 0 VDC |
| 1775633644 | 181 Count | 298 Count | 89 Count | 0 VDC | 0 VDC |
| 1775632743 | 178 Count | 295 Count | 87 Count | 0 VDC | 0 VDC |
| 1775631842 | 176 Count | 294 Count | 86 Count | 0 VDC | 0 VDC |
| 1775630942 | 173 Count | 291 Count | 84 Count | 0 VDC | 0 VDC |
| 1775630041 | 170 Count | 289 Count | 82 Count | 0 VDC | 0 VDC |
| 1775629140 | 167 Count | 287 Count | 80 Count | 0 VDC | 0 VDC |
| 1775628253 | 165 Count | 285 Count | 79 Count | 0 VDC | 0 VDC |
| 1775627352 | 163 Count | 282 Count | 78 Count | 0 VDC | 0 VDC |
| 1775626452 | 161 Count | 281 Count | 77 Count | 0 VDC | 0 VDC |
| 1775625551 | 159 Count | 280 Count | 76 Count | 0 VDC | 0 VDC |
| 1775624650 | 157 Count | 279 Count | 75 Count | 0 VDC | 0 VDC |
| 1775623750 | 155 Count | 278 Count | 74 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)