This is the latest recevied telemetry packets stored in our database for station/object DO2HN-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Celsius* | Rel_Hum* | Atm_Press* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1781156301 | 14.2 C | 58.07 % | 1020.13 hPa | 0 | 0 |
| 1781156285 | 14.2 C | 58.07 % | 1020.13 hPa | 0 | 0 |
| 1781156269 | 13.5 C | 58.36 % | 1020.5 hPa | 0 | 0 |
| 1781156253 | 13.5 C | 58.36 % | 1020.5 hPa | 0 | 0 |
| 1781156237 | 13.5 C | 58.36 % | 1020.5 hPa | 0 | 0 |
| 1781156221 | 12.9 C | 58.01 % | 1019.38 hPa | 0 | 0 |
| 1781156205 | 12.9 C | 58.01 % | 1020.13 hPa | 0 | 0 |
| 1781156162 | 12.9 C | 58.01 % | 1020.75 hPa | 0 | 0 |
| 1781156146 | 12.3 C | 57.3 % | 1019.75 hPa | 0 | 0 |
| 1781156130 | 12.3 C | 57.3 % | 1019.38 hPa | 0 | 0 |
| 1781156113 | 12.3 C | 57.3 % | 1019.5 hPa | 0 | 0 |
| 1781156097 | 12.3 C | 57.3 % | 1019.88 hPa | 0 | 0 |
| 1781155976 | 11.7 C | 57.18 % | 988.13 hPa | 0 | 0 |
| 1781086489 | 24 C | 39.22 % | 1020.75 hPa | 0 | 0 |
| 1781085585 | 24.3 C | 37.92 % | 1022.38 hPa | 0 | 0 |
| 1781084681 | 24.9 C | 37.11 % | 1020.75 hPa | 0 | 0 |
| 1781083777 | 25.2 C | 37.5 % | 1020.88 hPa | 0 | 0 |
| 1781083725 | 25.3 C | 37.43 % | 1021.25 hPa | 0 | 0 |
| 1781083709 | 25.3 C | 37.43 % | 1020.13 hPa | 0 | 0 |
| 1781083426 | 25.5 C | 37.6 % | 1020 hPa | 0 | 0 |
| 1781082522 | 25.6 C | 37.87 % | 1022.25 hPa | 0 | 0 |
*Used Equation Coefficients:
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)