This is the latest recevied telemetry packets stored in our database for station/object LU6EEG-11. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1773639315 | 211 Count | 228 Count | 170 Count | 4.22 VDC | 0 VDC |
| 1773638414 | 207 Count | 225 Count | 167 Count | 4.23 VDC | 0 VDC |
| 1773637514 | 203 Count | 221 Count | 164 Count | 4.14 VDC | 0 VDC |
| 1773636627 | 200 Count | 219 Count | 162 Count | 4.15 VDC | 0 VDC |
| 1773635726 | 196 Count | 215 Count | 159 Count | 4.25 VDC | 0 VDC |
| 1773634825 | 192 Count | 212 Count | 156 Count | 4.2 VDC | 0 VDC |
| 1773633925 | 188 Count | 208 Count | 153 Count | 4.21 VDC | 0 VDC |
| 1773633024 | 183 Count | 204 Count | 149 Count | 4.2 VDC | 0 VDC |
| 1773632124 | 179 Count | 201 Count | 146 Count | 4.23 VDC | 0 VDC |
| 1773631223 | 174 Count | 196 Count | 142 Count | 4.2 VDC | 0 VDC |
| 1773630322 | 171 Count | 194 Count | 140 Count | 4.24 VDC | 0 VDC |
| 1773629422 | 167 Count | 189 Count | 137 Count | 4.22 VDC | 0 VDC |
| 1773628521 | 163 Count | 186 Count | 134 Count | 4.17 VDC | 0 VDC |
| 1773627620 | 159 Count | 182 Count | 131 Count | 4.15 VDC | 0 VDC |
| 1773626720 | 154 Count | 178 Count | 127 Count | 4.26 VDC | 0 VDC |
| 1773625819 | 149 Count | 174 Count | 123 Count | 4.18 VDC | 0 VDC |
| 1773624918 | 145 Count | 170 Count | 120 Count | 4.23 VDC | 0 VDC |
| 1773624018 | 140 Count | 165 Count | 116 Count | 4.23 VDC | 0 VDC |
| 1773623117 | 136 Count | 161 Count | 113 Count | 4.2 VDC | 0 VDC |
| 1773622216 | 130 Count | 154 Count | 108 Count | 4.22 VDC | 0 VDC |
| 1773621316 | 123 Count | 146 Count | 102 Count | 4.18 VDC | 0 VDC |
| 1773620415 | 119 Count | 141 Count | 99 Count | 4.23 VDC | 0 VDC |
| 1773619514 | 114 Count | 135 Count | 95 Count | 4.18 VDC | 0 VDC |
| 1773618614 | 108 Count | 128 Count | 90 Count | 4.18 VDC | 0 VDC |
| 1773617713 | 102 Count | 121 Count | 85 Count | 4.25 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)