This is the latest recevied telemetry packets stored in our database for station/object DO1WKO-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Voltage* | Celsius* | Rel_Hum* | Atm_Press* | Value5* |
|---|---|---|---|---|---|
| 1779063991 | 3.26 VDC | 19.6 C | 40.61 % | 1012.75 hPa | 0 |
| 1779063088 | 3.27 VDC | 19.6 C | 40.57 % | 1013.13 hPa | 0 |
| 1779062185 | 3.29 VDC | 19.7 C | 40.29 % | 1013.38 hPa | 0 |
| 1779061282 | 3.3 VDC | 19.7 C | 40.63 % | 1014.88 hPa | 0 |
| 1779060379 | 3.31 VDC | 19.8 C | 40.37 % | 1015 hPa | 0 |
| 1779059476 | 3.32 VDC | 19.9 C | 40.05 % | 1015 hPa | 0 |
| 1779058573 | 3.33 VDC | 19.9 C | 40.13 % | 1014.25 hPa | 0 |
| 1779057670 | 3.34 VDC | 20 C | 39.93 % | 1012.75 hPa | 0 |
| 1779056767 | 3.36 VDC | 20.1 C | 40.04 % | 1014.13 hPa | 0 |
| 1779055864 | 3.37 VDC | 20.1 C | 40.12 % | 1016.13 hPa | 0 |
| 1779054961 | 3.38 VDC | 20.2 C | 39.94 % | 1014.63 hPa | 0 |
| 1779054058 | 3.4 VDC | 20.3 C | 39.53 % | 1023.63 hPa | 0 |
| 1779053155 | 3.42 VDC | 20.4 C | 39.74 % | 1017.25 hPa | 0 |
| 1779052252 | 3.43 VDC | 20.5 C | 39.52 % | 1015.63 hPa | 0 |
| 1779051349 | 3.44 VDC | 20.6 C | 39.44 % | 1016 hPa | 0 |
| 1779050446 | 3.45 VDC | 20.7 C | 39.44 % | 1015.63 hPa | 0 |
| 1779049543 | 3.46 VDC | 20.8 C | 39.53 % | 1015.25 hPa | 0 |
| 1779048640 | 3.47 VDC | 20.8 C | 39.48 % | 1014.88 hPa | 0 |
| 1779047737 | 3.48 VDC | 20.7 C | 39.91 % | 1017 hPa | 0 |
| 1779046834 | 3.49 VDC | 20.7 C | 40.08 % | 1015.25 hPa | 0 |
| 1779045931 | 3.5 VDC | 20.8 C | 40.15 % | 1013.88 hPa | 0 |
| 1779045028 | 3.51 VDC | 20.8 C | 40.41 % | 1013.63 hPa | 0 |
| 1779044125 | 3.52 VDC | 20.8 C | 40.18 % | 1015.38 hPa | 0 |
| 1779043222 | 3.52 VDC | 20.7 C | 40.26 % | 1014.5 hPa | 0 |
| 1779042319 | 3.53 VDC | 20.8 C | 39.76 % | 1014.13 hPa | 0 |
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)