This is the latest recevied telemetry packets stored in our database for station/object XE2B-29. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Voltage* | Celsius* | Rel_Hum* | Atm_Press* | Value5* |
|---|---|---|---|---|---|
| 1779030638 | 4.09 VDC | 28.7 C | 37.39 % | 0 hPa | 0 |
| 1779023193 | 4.09 VDC | 26.8 C | 37.74 % | 0 hPa | 0 |
| 1779017756 | 4.09 VDC | 27.8 C | 37.22 % | 1032.13 hPa | 0 |
| 1779013563 | 4.1 VDC | 28.8 C | 36.76 % | 0 hPa | 0 |
| 1779006203 | 4.1 VDC | 30.5 C | 36.84 % | 0 hPa | 0 |
| 1779003630 | 4.1 VDC | 30.9 C | 36.76 % | 0 hPa | 0 |
| 1779000682 | 4.1 VDC | 31.4 C | 36.41 % | 0 hPa | 0 |
| 1778998021 | 4.1 VDC | 31.9 C | 36.27 % | 0 hPa | 0 |
| 1778990648 | 4.1 VDC | 33.4 C | 35.69 % | 0 hPa | 0 |
| 1778983243 | 4.1 VDC | 34.9 C | 35.61 % | 0 hPa | 0 |
| 1778977553 | 4.1 VDC | 35.7 C | 35.35 % | 0 hPa | 0 |
| 1778972854 | 4.1 VDC | 35.8 C | 34.91 % | 1029.13 hPa | 0 |
| 1778966823 | 4.1 VDC | 35.8 C | 34.11 % | 0 hPa | 0 |
| 1778965581 | 4.11 VDC | 35.7 C | 34.25 % | 0 hPa | 0 |
| 1778964439 | 4.11 VDC | 35.7 C | 34.57 % | 0 hPa | 0 |
| 1778961753 | 4.11 VDC | 35.6 C | 34.05 % | 0 hPa | 0 |
| 1778952726 | 4.11 VDC | 34.2 C | 34.42 % | 0 hPa | 0 |
| 1778947248 | 4.11 VDC | 31.6 C | 29.73 % | 0 hPa | 0 |
| 1778946840 | 4.11 VDC | 32.2 C | 29.21 % | 0 hPa | 0 |
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)