This is the latest recevied telemetry packets stored in our database for station/object SR8DBN-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1787111219 | 281 Count | 48 Count | 48 Count | 4.07 VDC | 0 VDC |
| 1787109419 | 280 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787107618 | 279 Count | 48 Count | 48 Count | 4.07 VDC | 0 VDC |
| 1787105817 | 278 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787104016 | 277 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787102224 | 276 Count | 48 Count | 48 Count | 4.07 VDC | 0 VDC |
| 1787100423 | 275 Count | 48 Count | 48 Count | 4.07 VDC | 0 VDC |
| 1787098623 | 274 Count | 48 Count | 48 Count | 4.09 VDC | 0 VDC |
| 1787096822 | 273 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787095021 | 272 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787093220 | 271 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787091420 | 270 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787089619 | 269 Count | 48 Count | 48 Count | 4.09 VDC | 0 VDC |
| 1787087818 | 268 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787086017 | 267 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787084216 | 266 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787082416 | 265 Count | 48 Count | 48 Count | 4.09 VDC | 0 VDC |
| 1787080623 | 264 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787078822 | 263 Count | 48 Count | 48 Count | 4.09 VDC | 0 VDC |
| 1787077022 | 262 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787075221 | 261 Count | 48 Count | 48 Count | 4.08 VDC | 0 VDC |
| 1787073420 | 260 Count | 48 Count | 48 Count | 4.09 VDC | 0 VDC |
| 1787071619 | 259 Count | 48 Count | 48 Count | 4.09 VDC | 0 VDC |
| 1787069819 | 258 Count | 48 Count | 48 Count | 4.09 VDC | 0 VDC |
| 1787068018 | 256 Count | 47 Count | 47 Count | 4.09 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)