This is the latest recevied telemetry packets stored in our database for station/object HS9BZG. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TEMP* | HUM* | BAR* | BAT* | CPU* |
|---|---|---|---|---|---|
| 1783380573 | 33.49 °C | 52.2 %RH | 990.5 hPa | 4.2 V | 48.9 °C |
| 1783379973 | 33.42 °C | 52.3 %RH | 990.5 hPa | 4.2 V | 48.9 °C |
| 1783379373 | 33.09 °C | 52.9 %RH | 990.5 hPa | 4.2 V | 47.9 °C |
| 1783378773 | 32.73 °C | 53.1 %RH | 990.5 hPa | 4.13 V | 47.9 °C |
| 1783378173 | 33.15 °C | 52.3 %RH | 990.3 hPa | 4.15 V | 47.9 °C |
| 1783377573 | 33.29 °C | 52.1 %RH | 990.2 hPa | 4.2 V | 47.9 °C |
| 1783376973 | 33.33 °C | 52 %RH | 990.1 hPa | 4.2 V | 47.9 °C |
| 1783376373 | 33.35 °C | 51.9 %RH | 990.1 hPa | 4.2 V | 47.9 °C |
| 1783375773 | 33.36 °C | 51.8 %RH | 990 hPa | 4.2 V | 47.9 °C |
| 1783375173 | 33.39 °C | 51.7 %RH | 990 hPa | 4.2 V | 47.9 °C |
| 1783374573 | 33.42 °C | 51.6 %RH | 990 hPa | 4.2 V | 47.9 °C |
| 1783373973 | 33.4 °C | 51.5 %RH | 990 hPa | 4.2 V | 47.9 °C |
| 1783373373 | 33.51 °C | 51.3 %RH | 989.9 hPa | 4.2 V | 47.9 °C |
| 1783372773 | 33.56 °C | 51.1 %RH | 989.8 hPa | 4.2 V | 48.9 °C |
| 1783372173 | 33.59 °C | 51 %RH | 989.7 hPa | 4.2 V | 48.9 °C |
| 1783371573 | 33.62 °C | 51 %RH | 989.7 hPa | 4.2 V | 48.9 °C |
| 1783370973 | 33.42 °C | 51.3 %RH | 989.8 hPa | 4.2 V | 47.9 °C |
| 1783370373 | 33.1 °C | 51.5 %RH | 989.8 hPa | 4.12 V | 47.9 °C |
*Used Equation Coefficients:
TEMP: 0, 0.01, 0
HUM: 0, 0.1, 0
BAR: 0, 0.1, 800
BAT: 0, 0.01, 0
CPU: 0, 0.01, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)