This is the latest recevied telemetry packets stored in our database for station/object OK2ILA-5. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Voltage* | Celsius* | Rel_Hum* | Atm_Press* | Value5* |
|---|---|---|---|---|---|
| 1764945727 | 3.64 VDC | 19.9 C | 65.76 % | 1014.13 hPa | 0 |
| 1764945124 | 3.65 VDC | 19.9 C | 65.89 % | 1013.13 hPa | 0 |
| 1764944521 | 3.65 VDC | 19.9 C | 65.99 % | 1012.5 hPa | 0 |
| 1764943918 | 3.66 VDC | 19.7 C | 66.33 % | 1012.75 hPa | 0 |
| 1764943315 | 3.66 VDC | 19.7 C | 66.44 % | 1012.38 hPa | 0 |
| 1764942712 | 3.67 VDC | 19.6 C | 66.6 % | 1013.13 hPa | 0 |
| 1764942109 | 3.67 VDC | 19.5 C | 66.79 % | 1013 hPa | 0 |
| 1764941506 | 3.68 VDC | 19.4 C | 66.83 % | 1011.63 hPa | 0 |
| 1764940903 | 3.68 VDC | 19.3 C | 67.05 % | 1012.13 hPa | 0 |
| 1764940300 | 3.69 VDC | 19.3 C | 66.79 % | 1011.5 hPa | 0 |
| 1764939697 | 3.69 VDC | 19.3 C | 66.95 % | 1011.5 hPa | 0 |
| 1764939094 | 3.7 VDC | 19.3 C | 66.83 % | 1011.75 hPa | 0 |
| 1764938491 | 3.7 VDC | 19.3 C | 67.01 % | 1012.25 hPa | 0 |
| 1764937888 | 3.71 VDC | 19.3 C | 66.99 % | 1012 hPa | 0 |
| 1764937285 | 3.71 VDC | 19.4 C | 67.2 % | 1011.38 hPa | 0 |
| 1764936687 | 3.72 VDC | 19.4 C | 67.21 % | 1011.75 hPa | 0 |
| 1764936079 | 3.72 VDC | 19.4 C | 67.29 % | 1011.5 hPa | 0 |
| 1764935476 | 3.73 VDC | 19.4 C | 67.21 % | 1011.63 hPa | 0 |
| 1764934873 | 3.73 VDC | 19.4 C | 67.23 % | 1010.5 hPa | 0 |
| 1764934270 | 3.74 VDC | 19.5 C | 67.28 % | 1012.25 hPa | 0 |
| 1764933667 | 3.74 VDC | 19.5 C | 67.19 % | 1012.38 hPa | 0 |
| 1764933069 | 3.75 VDC | 19.5 C | 67.39 % | 1011.13 hPa | 0 |
| 1764932461 | 3.75 VDC | 19.5 C | 67.49 % | 1012.5 hPa | 0 |
| 1764931858 | 3.76 VDC | 19.6 C | 67.53 % | 1011.88 hPa | 0 |
| 1764931255 | 3.76 VDC | 19.6 C | 67.43 % | 1012 hPa | 0 |
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)