This is the latest recevied telemetry packets stored in our database for station/object SP9CXD-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1786715539 | 926 Count | 802 Count | 45 Count | 4.26 VDC | 0 VDC |
| 1786715479 | 925 Count | 802 Count | 45 Count | 4.26 VDC | 0 VDC |
| 1786714751 | 913 Count | 802 Count | 45 Count | 4.33 VDC | 0 VDC |
| 1786713477 | 892 Count | 802 Count | 45 Count | 4.24 VDC | 0 VDC |
| 1786713417 | 891 Count | 802 Count | 45 Count | 4.26 VDC | 0 VDC |
| 1786713295 | 889 Count | 802 Count | 45 Count | 4.32 VDC | 0 VDC |
| 1786713114 | 886 Count | 802 Count | 45 Count | 4.25 VDC | 0 VDC |
| 1786712992 | 884 Count | 802 Count | 45 Count | 4.27 VDC | 0 VDC |
| 1786712932 | 883 Count | 802 Count | 45 Count | 4.31 VDC | 0 VDC |
| 1786709951 | 832 Count | 802 Count | 45 Count | 4.31 VDC | 0 VDC |
| 1786708815 | 813 Count | 802 Count | 45 Count | 4.28 VDC | 0 VDC |
| 1786708754 | 812 Count | 802 Count | 45 Count | 4.31 VDC | 0 VDC |
| 1786707965 | 799 Count | 802 Count | 45 Count | 4.28 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)