This is the latest recevied telemetry packets stored in our database for station/object OK1FWG-6. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
---|---|---|---|---|---|
1757875854 | 577 Count | 604 Count | 507 Count | 3.92 VDC | 0 VDC |
1757874051 | 572 Count | 599 Count | 503 Count | 3.84 VDC | 0 VDC |
1757872248 | 567 Count | 594 Count | 499 Count | 3.91 VDC | 0 VDC |
1757870445 | 558 Count | 585 Count | 491 Count | 3.84 VDC | 0 VDC |
1757868641 | 546 Count | 573 Count | 480 Count | 3.93 VDC | 0 VDC |
1757866838 | 531 Count | 557 Count | 466 Count | 3.92 VDC | 0 VDC |
1757865035 | 480 Count | 506 Count | 416 Count | 3.89 VDC | 0 VDC |
1757863232 | 466 Count | 492 Count | 403 Count | 3.93 VDC | 0 VDC |
1757861429 | 462 Count | 488 Count | 400 Count | 3.85 VDC | 0 VDC |
1757859626 | 456 Count | 482 Count | 395 Count | 3.88 VDC | 0 VDC |
1757857823 | 450 Count | 476 Count | 390 Count | 3.84 VDC | 0 VDC |
1757856020 | 436 Count | 463 Count | 377 Count | 3.89 VDC | 0 VDC |
1757854217 | 432 Count | 459 Count | 374 Count | 3.9 VDC | 0 VDC |
1757852414 | 413 Count | 441 Count | 356 Count | 3.89 VDC | 0 VDC |
1757850611 | 409 Count | 435 Count | 353 Count | 3.88 VDC | 0 VDC |
1757848808 | 405 Count | 430 Count | 350 Count | 3.85 VDC | 0 VDC |
1757847005 | 400 Count | 425 Count | 346 Count | 3.89 VDC | 0 VDC |
1757845202 | 387 Count | 412 Count | 334 Count | 3.86 VDC | 0 VDC |
1757843399 | 381 Count | 404 Count | 329 Count | 3.91 VDC | 0 VDC |
1757841596 | 375 Count | 398 Count | 324 Count | 3.85 VDC | 0 VDC |
1757839793 | 369 Count | 392 Count | 319 Count | 3.85 VDC | 0 VDC |
1757837990 | 362 Count | 386 Count | 313 Count | 3.9 VDC | 0 VDC |
1757836187 | 349 Count | 372 Count | 301 Count | 3.93 VDC | 0 VDC |
1757834383 | 339 Count | 362 Count | 292 Count | 3.93 VDC | 0 VDC |
1757832581 | 336 Count | 359 Count | 290 Count | 3.86 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)