This is the latest recevied telemetry packets stored in our database for station/object N7UV-8. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Voltage* | Celsius* | Rel_Hum* | Atm_Press* | Value5* |
|---|---|---|---|---|---|
| 1773673086 | 4.19 VDC | 27.8 C | 21.7 % | 1016.25 hPa | 0 |
| 1773672815 | 4.19 VDC | 27.5 C | 20.74 % | 1015.63 hPa | 0 |
| 1773672572 | 4.19 VDC | 27.2 C | 20.77 % | 1015.5 hPa | 0 |
| 1773671930 | 4.19 VDC | 27.3 C | 18.29 % | 1015.5 hPa | 0 |
| 1773668070 | 4.19 VDC | 27.8 C | 18.08 % | 1016.75 hPa | 0 |
| 1773659060 | 4.19 VDC | 29.6 C | 17.8 % | 1017 hPa | 0 |
| 1773650049 | 4.19 VDC | 32 C | 17.26 % | 1015.75 hPa | 0 |
| 1773641039 | 4.19 VDC | 34.7 C | 17.12 % | 1013.38 hPa | 0 |
| 1773632030 | 4.19 VDC | 35.6 C | 17.77 % | 1012.25 hPa | 0 |
| 1773627444 | 4.19 VDC | 34.4 C | 19.1 % | 1011.38 hPa | 0 |
| 1773627271 | 4.19 VDC | 34.7 C | 18.12 % | 1010.88 hPa | 0 |
| 1773627096 | 4.19 VDC | 34.9 C | 18.33 % | 1011.5 hPa | 0 |
| 1773623278 | 4.19 VDC | 34.6 C | 19.16 % | 1011.88 hPa | 0 |
| 1773622935 | 4.19 VDC | 35.7 C | 18.89 % | 1011.5 hPa | 0 |
| 1773620685 | 4.19 VDC | 32.4 C | 18.91 % | 1013 hPa | 0 |
| 1773620397 | 4.19 VDC | 32.9 C | 18.51 % | 1011.13 hPa | 0 |
| 1773619900 | 4.19 VDC | 33.8 C | 17.81 % | 1011.88 hPa | 0 |
| 1773619787 | 4.19 VDC | 33.8 C | 18.02 % | 1011.75 hPa | 0 |
| 1773619527 | 4.19 VDC | 34.4 C | 17.94 % | 1012.13 hPa | 0 |
| 1773619321 | 4.19 VDC | 35.2 C | 17.53 % | 1012.13 hPa | 0 |
| 1773619056 | 4.19 VDC | 36.2 C | 17 % | 1011.25 hPa | 0 |
| 1773618750 | 4.19 VDC | 37.1 C | 16.7 % | 1010.88 hPa | 0 |
| 1773618281 | 4.19 VDC | 36.7 C | 16.33 % | 1009.63 hPa | 0 |
| 1773617875 | 4.19 VDC | 36.2 C | 15.84 % | 1011.25 hPa | 0 |
| 1773617522 | 4.19 VDC | 35.8 C | 15.26 % | 1009.75 hPa | 0 |
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)