This is the latest recevied telemetry packets stored in our database for station/object OZ1MAS-11. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
---|---|---|---|---|---|
1751685790 | 462 Count | 187 Count | 158 Count | 0 VDC | 0 VDC |
1751684885 | 460 Count | 186 Count | 157 Count | 0 VDC | 0 VDC |
1751683981 | 458 Count | 185 Count | 156 Count | 0 VDC | 0 VDC |
1751683077 | 456 Count | 184 Count | 155 Count | 0 VDC | 0 VDC |
1751682172 | 454 Count | 183 Count | 154 Count | 0 VDC | 0 VDC |
1751681268 | 452 Count | 182 Count | 153 Count | 0 VDC | 0 VDC |
1751680363 | 450 Count | 181 Count | 152 Count | 0 VDC | 0 VDC |
1751679459 | 448 Count | 180 Count | 151 Count | 0 VDC | 0 VDC |
1751678554 | 446 Count | 179 Count | 150 Count | 0 VDC | 0 VDC |
1751677650 | 444 Count | 178 Count | 149 Count | 0 VDC | 0 VDC |
1751676746 | 442 Count | 177 Count | 148 Count | 0 VDC | 0 VDC |
1751675841 | 440 Count | 176 Count | 147 Count | 0 VDC | 0 VDC |
1751675043 | 438 Count | 175 Count | 146 Count | 0 VDC | 0 VDC |
1751674139 | 436 Count | 174 Count | 145 Count | 0 VDC | 0 VDC |
1751673234 | 434 Count | 173 Count | 144 Count | 0 VDC | 0 VDC |
1751672330 | 432 Count | 172 Count | 143 Count | 0 VDC | 0 VDC |
1751671425 | 430 Count | 171 Count | 142 Count | 0 VDC | 0 VDC |
1751670521 | 428 Count | 170 Count | 141 Count | 0 VDC | 0 VDC |
1751669616 | 426 Count | 169 Count | 140 Count | 0 VDC | 0 VDC |
1751668712 | 424 Count | 168 Count | 139 Count | 0 VDC | 0 VDC |
1751667808 | 422 Count | 167 Count | 138 Count | 0 VDC | 0 VDC |
1751666903 | 420 Count | 166 Count | 137 Count | 0 VDC | 0 VDC |
1751665999 | 418 Count | 165 Count | 136 Count | 0 VDC | 0 VDC |
1751665094 | 416 Count | 164 Count | 135 Count | 0 VDC | 0 VDC |
1751664190 | 414 Count | 163 Count | 134 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)