This is the latest recevied telemetry packets stored in our database for station/object F4IZM-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1789249972 | 637 Count | 814 Count | 418 Count | 0 VDC | 0 VDC |
| 1789248166 | 635 Count | 813 Count | 417 Count | 0 VDC | 0 VDC |
| 1789246361 | 633 Count | 812 Count | 416 Count | 0 VDC | 0 VDC |
| 1789244557 | 630 Count | 810 Count | 414 Count | 0 VDC | 0 VDC |
| 1789242752 | 627 Count | 808 Count | 412 Count | 0 VDC | 0 VDC |
| 1789240946 | 625 Count | 807 Count | 411 Count | 0 VDC | 0 VDC |
| 1789239141 | 623 Count | 806 Count | 410 Count | 0 VDC | 0 VDC |
| 1789237337 | 620 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789235532 | 619 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789233726 | 618 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789231921 | 617 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789230116 | 616 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789228312 | 615 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789226507 | 614 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789224702 | 613 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789222897 | 612 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789221092 | 611 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789219286 | 610 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789217481 | 609 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789215677 | 608 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789213872 | 607 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789212066 | 606 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789210261 | 605 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789208456 | 604 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
| 1789206652 | 603 Count | 804 Count | 408 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)