This is the latest recevied telemetry packets stored in our database for station/object SQ2WSZ-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1789237549 | 325 Count | 475 Count | 310 Count | 0 VDC | 0 VDC |
| 1789236949 | 300 Count | 435 Count | 286 Count | 0 VDC | 0 VDC |
| 1789236348 | 278 Count | 401 Count | 265 Count | 0 VDC | 0 VDC |
| 1789235747 | 252 Count | 360 Count | 240 Count | 0 VDC | 0 VDC |
| 1789235147 | 222 Count | 316 Count | 211 Count | 0 VDC | 0 VDC |
| 1789233945 | 166 Count | 232 Count | 157 Count | 0 VDC | 0 VDC |
| 1789233344 | 136 Count | 184 Count | 128 Count | 0 VDC | 0 VDC |
| 1789232771 | 108 Count | 150 Count | 105 Count | 0 VDC | 0 VDC |
| 1789232170 | 78 Count | 106 Count | 76 Count | 0 VDC | 0 VDC |
| 1789231569 | 49 Count | 64 Count | 48 Count | 0 VDC | 0 VDC |
| 1789230967 | 25 Count | 35 Count | 25 Count | 0 VDC | 0 VDC |
| 1789230366 | 669 Count | 1031 Count | 642 Count | 0 VDC | 0 VDC |
| 1789229766 | 644 Count | 993 Count | 618 Count | 0 VDC | 0 VDC |
| 1789229165 | 621 Count | 957 Count | 596 Count | 0 VDC | 0 VDC |
| 1789228564 | 595 Count | 920 Count | 571 Count | 0 VDC | 0 VDC |
| 1789227964 | 571 Count | 882 Count | 548 Count | 0 VDC | 0 VDC |
| 1789227363 | 547 Count | 846 Count | 525 Count | 0 VDC | 0 VDC |
| 1789226762 | 520 Count | 809 Count | 499 Count | 0 VDC | 0 VDC |
| 1789226161 | 497 Count | 775 Count | 477 Count | 0 VDC | 0 VDC |
| 1789225560 | 470 Count | 735 Count | 451 Count | 0 VDC | 0 VDC |
| 1789224960 | 444 Count | 693 Count | 426 Count | 0 VDC | 0 VDC |
| 1789224359 | 418 Count | 655 Count | 401 Count | 0 VDC | 0 VDC |
| 1789223758 | 399 Count | 631 Count | 383 Count | 0 VDC | 0 VDC |
| 1789223161 | 372 Count | 587 Count | 357 Count | 0 VDC | 0 VDC |
| 1789222557 | 348 Count | 549 Count | 334 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)