This is the latest recevied telemetry packets stored in our database for station/object OK0HCS-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
---|---|---|---|---|---|
1756478947 | 21 Count | 592 Count | 0 Count | 0 VDC | 0 VDC |
1756477144 | 20 Count | 548 Count | 0 Count | 0 VDC | 0 VDC |
1756475340 | 18 Count | 506 Count | 0 Count | 0 VDC | 0 VDC |
1756473537 | 17 Count | 454 Count | 0 Count | 0 VDC | 0 VDC |
1756471734 | 15 Count | 402 Count | 0 Count | 0 VDC | 0 VDC |
1756469930 | 14 Count | 367 Count | 0 Count | 0 VDC | 0 VDC |
1756468127 | 12 Count | 324 Count | 0 Count | 0 VDC | 0 VDC |
1756466359 | 11 Count | 289 Count | 0 Count | 0 VDC | 0 VDC |
1756464556 | 8 Count | 253 Count | 0 Count | 0 VDC | 0 VDC |
1756462753 | 7 Count | 211 Count | 0 Count | 0 VDC | 0 VDC |
1756460950 | 5 Count | 176 Count | 0 Count | 0 VDC | 0 VDC |
1756459147 | 4 Count | 143 Count | 0 Count | 0 VDC | 0 VDC |
1756457344 | 2 Count | 86 Count | 0 Count | 0 VDC | 0 VDC |
1756455540 | 1 Count | 44 Count | 0 Count | 0 VDC | 0 VDC |
1756453737 | 40 Count | 1005 Count | 0 Count | 0 VDC | 0 VDC |
1756451934 | 39 Count | 971 Count | 0 Count | 0 VDC | 0 VDC |
1756450131 | 37 Count | 936 Count | 0 Count | 0 VDC | 0 VDC |
1756448328 | 36 Count | 890 Count | 0 Count | 0 VDC | 0 VDC |
1756446525 | 34 Count | 841 Count | 0 Count | 0 VDC | 0 VDC |
1756444758 | 33 Count | 792 Count | 0 Count | 0 VDC | 0 VDC |
1756442955 | 30 Count | 758 Count | 0 Count | 0 VDC | 0 VDC |
1756441152 | 29 Count | 722 Count | 0 Count | 0 VDC | 0 VDC |
1756439348 | 27 Count | 683 Count | 0 Count | 0 VDC | 0 VDC |
1756437545 | 26 Count | 649 Count | 0 Count | 0 VDC | 0 VDC |
1756435742 | 24 Count | 611 Count | 0 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)