This is the latest recevied telemetry packets stored in our database for station/object EB5BZM-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1793008562 | 9 Count | 968 Count | 0 Count | 0 VDC | 0 VDC |
| 1793006519 | 8 Count | 826 Count | 0 Count | 0 VDC | 0 VDC |
| 1793004476 | 7 Count | 728 Count | 0 Count | 0 VDC | 0 VDC |
| 1793002432 | 6 Count | 604 Count | 0 Count | 0 VDC | 0 VDC |
| 1793000389 | 5 Count | 472 Count | 0 Count | 0 VDC | 0 VDC |
| 1792998346 | 4 Count | 366 Count | 0 Count | 0 VDC | 0 VDC |
| 1792996302 | 3 Count | 290 Count | 0 Count | 0 VDC | 0 VDC |
| 1792994259 | 2 Count | 206 Count | 0 Count | 0 VDC | 0 VDC |
| 1792992215 | 1 Count | 134 Count | 0 Count | 0 VDC | 0 VDC |
| 1792991051 | 0 Count | 87 Count | 0 Count | 0 VDC | 0 VDC |
| 1792989007 | 11 Count | 1042 Count | 0 Count | 0 VDC | 0 VDC |
| 1792986964 | 10 Count | 947 Count | 0 Count | 0 VDC | 0 VDC |
| 1792984920 | 9 Count | 860 Count | 0 Count | 0 VDC | 0 VDC |
| 1792982876 | 8 Count | 769 Count | 0 Count | 0 VDC | 0 VDC |
| 1792980833 | 7 Count | 674 Count | 0 Count | 0 VDC | 0 VDC |
| 1792978789 | 6 Count | 566 Count | 0 Count | 0 VDC | 0 VDC |
| 1792976746 | 5 Count | 474 Count | 0 Count | 0 VDC | 0 VDC |
| 1792974702 | 4 Count | 387 Count | 0 Count | 0 VDC | 0 VDC |
| 1792972659 | 3 Count | 304 Count | 0 Count | 0 VDC | 0 VDC |
| 1792970616 | 2 Count | 226 Count | 0 Count | 0 VDC | 0 VDC |
| 1792969449 | 1 Count | 184 Count | 0 Count | 0 VDC | 0 VDC |
| 1792967405 | 0 Count | 89 Count | 0 Count | 0 VDC | 0 VDC |
| 1792965362 | 9 Count | 1031 Count | 0 Count | 0 VDC | 0 VDC |
| 1792963318 | 8 Count | 951 Count | 0 Count | 0 VDC | 0 VDC |
| 1792961275 | 7 Count | 865 Count | 0 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)