This is the latest recevied telemetry packets stored in our database for station/object SQ2CPA-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
---|---|---|---|---|---|
1744997406 | 22 Count | 553 Count | 0 Count | 4.14 VDC | 2.86 VDC |
1744995607 | 21 Count | 392 Count | 0 Count | 4.14 VDC | 4.7 VDC |
1744993809 | 20 Count | 376 Count | 0 Count | 4.15 VDC | 4.68 VDC |
1744992010 | 19 Count | 359 Count | 0 Count | 4.14 VDC | 5.8 VDC |
1744990211 | 18 Count | 343 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744988411 | 17 Count | 327 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744986614 | 16 Count | 310 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744984814 | 15 Count | 294 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744983014 | 14 Count | 277 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744981215 | 13 Count | 261 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744979416 | 12 Count | 246 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744977618 | 11 Count | 231 Count | 0 Count | 4.14 VDC | 5.82 VDC |
1744975818 | 10 Count | 216 Count | 0 Count | 4.15 VDC | 5.84 VDC |
1744974018 | 9 Count | 200 Count | 0 Count | 4.15 VDC | 5.84 VDC |
1744970420 | 7 Count | 171 Count | 0 Count | 4.15 VDC | 5.82 VDC |
1744968621 | 6 Count | 157 Count | 0 Count | 4.15 VDC | 5.82 VDC |
1744966822 | 5 Count | 103 Count | 0 Count | 4.15 VDC | 5.82 VDC |
1744965024 | 4 Count | 81 Count | 0 Count | 4.15 VDC | 5.8 VDC |
1744963225 | 3 Count | 65 Count | 0 Count | 4.15 VDC | 5.82 VDC |
1744961427 | 2 Count | 48 Count | 0 Count | 4.15 VDC | 5.8 VDC |
1744959628 | 1 Count | 32 Count | 0 Count | 4.16 VDC | 5.8 VDC |
1744957829 | 0 Count | 15 Count | 0 Count | 4.16 VDC | 5.82 VDC |
1744956030 | 55 Count | 1016 Count | 0 Count | 4.16 VDC | 5.8 VDC |
1744954232 | 54 Count | 999 Count | 0 Count | 4.16 VDC | 5.78 VDC |
1744952433 | 53 Count | 983 Count | 0 Count | 4.16 VDC | 4.66 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)